New York State Energy Conservation Construction Code
Building Design by Acceptable Practice:
This establishes criteria for the design of residential buildings; provided, however, that such residential buildings shall: contain no more than two dwelling units; have less than 5000 square feet in gross floor area; not exceed three stories in height; and have a wall glazing area that does not exceed 17% of the gross wall area.
Building Envelope Systems:
For nonelectric comfort heating; 7000-9000 Degree Days -
- Exterior Wall.............................R-18
- Roof/Ceiling..............................R-24
- Floor........................................R-19
- Foundation Wall.........................R-10
- Slab Edge Insulation...................R-10
- Glazing.....................................R-1.7
- Entrance Doors.........................R-2.5